How the flooring expansion gap calculator works
Most floors swell and shrink a little with heat and damp, so they need a small gap at every wall. Pick the type of floor, enter the size of the room and the conditions, and the calculator gives the gap to leave at the walls, the size of the floor after the gaps, the width of baseboard or shoe moulding needed to hide the gap, the number of spacers, and any T-moulding you need on a long run. A second tab checks the gap you already have, and a third tab compares six floor types in the same room.
The formula
Each floor type has a usual gap. The calculator adds 1/8 in for a humid or coastal home and 1/4 in for a sunroom, glass doors or big swings in temperature. The floor is then the room size minus two gaps in each direction. The moulding must cover the gap plus about 1/4 in. If the room is longer than the longest run advised for the floor, the floor is split with a T-moulding, which needs a gap on both sides.
Usual gaps by floor type
| Floor | Range | Suggested | Longest run |
|---|---|---|---|
| Laminate | 1/4 to 1/2 in | 3/8 in | about 30 ft |
| Engineered hardwood (floating) | 3/8 to 3/4 in | 1/2 in | about 40 ft |
| Solid hardwood (nailed) | 1/2 to 1 in | 3/4 in | no set limit |
| Vinyl plank (click) | 3/16 to 3/8 in | 1/4 in | about 50 ft |
| Bamboo (strand woven) | 3/8 to 3/4 in | 1/2 in | about 40 ft |
| Cork (floating) | 3/8 to 1/2 in | 1/2 in | about 30 ft |
Worked examples
A 34 ft by 14 ft room of laminate, normal conditions, 2 doorways, spacers every 18 in
Leave a gap of about 3/8 in. The floor is 33 ft 11 in by 13 ft 11 in, and the moulding must cover at least 5/8 in. You need about 68 spacers. The room is longer than 30 ft, so split the floor with a T-moulding, which gives 3 transitions with the 2 doorways.
A 12 ft by 10 ft room of nailed solid hardwood in a sunroom, 1 doorway
Leave a gap of about 1 in, since the sun adds 1/4 in. The moulding must cover at least 1 1/4 in. You need about 34 spacers and 41 ft of moulding.
Checking a laminate floor with a gap of 1/8 in
This is less than the smallest advised for laminate, about 1/4 in, so the calculator says the gap is too small, and the floor may buckle.
Checking a click vinyl floor with a gap of 3/4 in
This is wider than the 3/8 in usually needed, so the floor is safe, but the moulding must cover at least 1 in.
Common mistakes
- Fitting the floor tight to the wall. A floor with no gap can buckle when it swells.
- Fixing the baseboard to the floor. Fix it to the wall, so the floor can still move under it.
- Trapping a floating floor. Do not fix the floor under cabinets or an island, and keep a gap at pipes and door frames.
- Not splitting a long run. A floor longer than the maker advises needs a T-moulding, with a gap on both sides.
- Using the gap for a different floor. A gap right for vinyl is too small for solid wood.